3 Slotted Pvc Pipe
Shop undefined 3-in x 10-ft Corrugated Perforated Pipe in the Corrugated Drainage Pipe department at Lowe's.com. Perforated drain pipe used to move water away. Charlotte Pipe PVC Sewer and Drain Pipe 3 in. 0 Reviews $ Free Store Pickup Today. Showing 30 of 47.
- When it comes to PVC Pipe products, Grainger's got your back. Easy online ordering for the ones who get it done along with 24/7 customer service, free technical support & more.
- The friction head loss (feet H 2 O per 100 feet pipe) in straight plastic pipes made of PVC, PP, PE, PEH or similar - can be estimated from the table below. Head losses are calculated for PVC pipe Schedule 40 by using the Hazen-Williams equation and the Hazen-Williams roughness constant c = 145.
- Sioux Chief 878-035 - 3-1/2' Slotted Polypro Flush Plug w/o Threaded Brass Insert - Combine with FIP adapters to make your own cleanouts Glass-filled polypropylene plugs: Will not seize up on ABS or PVC Are acid resistant and chemically inert Are more durable than traditional plugs.
Friction head loss (ft/100 ft) in plastic pipes - PVC, PP, PE, PEH
The friction head loss(feet H2O per 100 feet pipe) in straight plastic pipes made of PVC, PP, PE, PEH or similar - can be estimated from the table below.
Head losses are calculated for PVC pipe Schedule 40 by using the Hazen-Williams equation and the Hazen-Williams roughness constant c = 145. Note that minor loss in fittings must be added when calculating total head loss in a pipe line.
For full table with larger dimensions - rotate the screen!
Friction Head Loss(ft H2O/100 ft pipe) | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Volume Flow | Nominal Pipe Diameter (inches) | |||||||||||
(GPM)1) | (GPH)2) | |||||||||||
3/8 | 1/2 | 3/4 | 1 | 1 1/4 | 1 1/2 | 2 | 2 1/2 | 3 | 4 | 6 | ||
Nominal Inside Diameter (inches) | ||||||||||||
0.493 | 0.622 | 0.824 | 1.049 | 1.380 | 1.610 | 2.067 | 2.469 | 3.068 | 4.026 | 6.065 | ||
1 | 60 | 3.3 | 1.1 | 0.3 | ||||||||
2 | 120 | 11.8 | 3.8 | 1.0 | 0.3 | 0.1 | ||||||
4 | 240 | 42.5 | 13.7 | 3.5 | 1.1 | 0.3 | 0.1 | |||||
5 | 300 | 64.2 | 20.7 | 5.3 | 1.6 | 0.4 | 0.2 | |||||
6 | 360 | 29.0 | 7.4 | 2.3 | 0.6 | 0.3 | ||||||
8 | 480 | 49.5 | 12.6 | 3.9 | 1.0 | 0.5 | 0.1 | |||||
10 | 600 | 74.7 | 19.0 | 5.9 | 1.6 | 0.7 | 0.2 | 0.1 | ||||
20 | 1200 | 68.6 | 21.2 | 5.6 | 2.6 | 0.8 | 0.3 | 0.1 | ||||
30 | 1800 | 11.8 | 5.6 | 1.7 | 0.7 | 0.2 | ||||||
40 | 2400 | 20.1 | 9.5 | 2.8 | 1.2 | 0.4 | 0.1 | |||||
50 | 3000 | 14.4 | 4.3 | 1.8 | 0.6 | 0.2 | ||||||
60 | 3600 | 20.1 | 6.0 | 2.5 | 0.9 | 0.2 | ||||||
70 | 4200 | 7.9 | 3.3 | 1.2 | 0.3 | |||||||
80 | 4800 | 10.2 | 4.3 | 1.5 | 0.4 | |||||||
90 | 5400 | 12.6 | 5.3 | 1.9 | 0.5 | |||||||
100 | 6000 | 6.5 | 2.3 | 0.6 | 0.1 | |||||||
125 | 7500 | 9.8 | 3.4 | 0.9 | 0.1 | |||||||
150 | 9000 | 4.8 | 1.3 | 0.2 |
1) GPM = US gallons per minute
2) GPH = US gallons per hour
- 1 US gallon/min = 6.30888x10-5 m3/s = 0.227 m3/h = 0.0631 dm3(liter)/s = 2.228x10-3 ft3/s = 0.1337 ft3/min = 0.8327 Imperial gal (UK)/min
- 1 ft H2O = 0.3048 m H2O = 0.4335 psi = 62.43 lbs/ft2
Example - Friction Head Loss in a Plastic Pipe
A flow of 10 GPM in a 2' pipe gives a head loss of 0.2 feet water column per 100 feet of pipe.
Related Topics
- Fluid Flow and Pressure Loss - Pipe lines - fluid flow and pressure loss - water, sewer, steel pipes, pvc pipes, copper tubes and more
Related Documents
- ASTM D1785 and ASTM F441 - PVC and CPVC Pipes Schedule 40 & 80 - Standard dimensions and weight of PVC - Polyvinyl Chloride - and CPVC - Chlorinated Polyvinyl Chloride
- ASTM D2241 - Poly(Vinyl Chloride) (PVC) Pressure-Rated Pipe (SDR Series) - Dimensions - Dimensions of PVC pipe SDR series
- ASTM D2846 - CPVC Plastic Hot and Cold Water Distribution Tubes - Dimensions - Dimensions of CTS - Copper Tube Sized CPVC (Chlorinated Poly Vinyl Chloride) tubes
- ASTM F2389 Pressure-rated Polypropylene (PP) - Dimensions - Dimensions of pressure rated PP pipes according ASTM F2389
- ASTM F876 - PEX Tube - Dimensions - Dimensions of PEX tubes
- BS 7291 - Thermoplastics pipes for hot and cold water - dimensions - Dimensions of thermoplastic pipes - PEX and PB according BS 7291
- CPVC Pipes - Operating and Collapsing Pressure Ratings - Maximum operating and bursting pressures of CPVC - Chlorinated Poly (Vinyl Chloride) - piping systems
- Hazen-Williams Coefficients - Hazen-Williams coefficients for piping materials
- Hazen-Williams Equation - calculating Head Loss in Water Pipes - Friction head loss (ftH2O per 100 ft pipe) in water pipes can be estimated with the empirical Hazen-Williams equation
- ISO 11922 - Thermoplastics pipes for the conveyance of fluids - Dimensions - Dimensions of plastic pipes according ISO 11922 - metric and imperial units
- Lined Pipes and Pressure Drop - Pressure drop diagrams for PTFE, PP, PFA and PVDF lined pipes
- PE - PolyEthylene Pipes, Flow and Pressure Loss - Water flow in SDR pressure rated PE-pipes - pressure loss and velocities - Imperial and SI units
- PE Pipes - Pressure Ratings - Water pressure ratings for schedule 40 and schedule 80 Polyethylene plastic pipes
- PE Pipes - Temperature and Pressure Ratings - PolyEthylene pipe - temperature and maximum operating pressure
- Plastic Pipes Operating Temperatures - ABS, PE, PVC, CPVC, PB, PP and SR - pressure and operating temperatures
- Plastics - Recycling Codes and Labels - Symbols used for recycling plastic products like bottles, containers and packaging
- PP - Polypropylene - Chemical Resistance - Chemical resistance of Polypropylene - PP - to acids, bases, organic substances and solvents
- PP Pipes - Support Spacing - Maximum distance between PolyPropylene pipes supports
- PVC - Friction Loss in Fittings and Equivalent Length - Minor loss in PVC and CPVC fittings as equivalent length of straight pipe
- PVC Pipes - Friction Loss and Flow Velocities Schedule 40 - Water flow in thermoplastic PVC and CPVC pipes Schedule 40 - friction loss (ft/100 ft, psi/100 ft) and flow velocities at dimensions ranging 1/2 to 16 inches
- PVC Pipes Schedule 40 - Friction loss and Velocity Diagrams - Friction loss (psi/100 ft) and velocity for water flow in plastic PVC pipe schedule 40
- Resistance and Fittings Equivalent Length in Hot Water Systems - Equivalent length of fittings like bends, returns, tees and valves in hot water heating systems - equivalent length in feet and meter
- SDR - Standard Dimension Ratio and S - Pipe Series - It is common to use the Standard Dimension Ratio - SDR - as method of rating pressure piping
- Thermoplastic Pipes - Temperature and Support Distance - Maximum space between supports for PVC, CPVC, PVDF and PP pipes
Tag Search
3 In Pvc Pipe Fittings
- en: major pressure loss plastic pipes
- es: grandes tubos de plástico de pérdida de presión
- de: Hauptdruckverlust Kunststoffrohren
Slotted PVC pipe and perforated pipes have a broad range of use in subsurface drainage systems. They are effective when used for drainage purposes such as in sports fields, roads, airports, agricultural fields and podium gardens among more. The slotted PVC pipe and perforated PVC pipes are available in 20mm to 400mm diameter size.
High performance slotted PVC pipe are made from the present fabrication technology to give a compliant range of PVC pipes that have a remarkable strength to withstand the conditions. The slotted PVC pipes are available either full threaded or slip joints. With the perfect material for to serve the intended purpose, they can be slotted depending on the specifications.
3 Inch Slotted Pvc Pipe
Showing all 3 results
3 Slotted Pvc Pipe
Slotted PVC Pipe
$18.22 – $332.22Slotted Stormwater Pipe
$87.53Slotted DWV Pipe
$48.70 – $103.46